Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EuroIntervention ; 10(11): e1-8, 2015 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-25169593

RESUMO

AIMS: The aim of this IVUS substudy was to assess the efficacy of the Y-shaped Medtronic bifurcation-dedicated stent (BDS) for the treatment of de novo coronary bifurcated lesions. METHODS AND RESULTS: In the BRANCH trial, post-procedure IVUS was performed in 45 patients. IVUS was available in both branches in 19 lesions and only the main branch (MB) in 26 lesions. IVUS analysis included four distinct locations: proximal MB, bifurcation site, distal MB, and side branch (SB). Lumen symmetry was calculated as minimum/maximum lumen diameters. The quantity of isolated stent struts across the SB ostium was used to assess inadequate strut apposition to the carina resulting in partial jailing of the SB orifice. A minimum stent area (MSA) <4 mm2 was found in 0% of proximal and distal MB, and in 15.4% of SB. In SB, MSA was located mainly at mid or distal segments (84.6%), rather than at the SB ostium. Eccentric stent expansion and edge dissection were seen primarily at proximal MB. Isolated struts were seen in only 20.9% of SB ostia with a minimum length of 0.7±0.4 mm. CONCLUSIONS: Implantation of BDS resulted in adequate stent dimensions and strut apposition at the carina and SB ostium. ClinicalTrials.gov Identifier: NCT00607321.


Assuntos
Angioplastia Coronária com Balão , Estenose Coronária/cirurgia , Stents , Idoso , Estudos de Coortes , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção
2.
Ann Thorac Surg ; 80(6): 2374-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16305919

RESUMO

Saphenous vein graft aneurysm is a potentially fatal complication of coronary artery bypass grafting and usually requires surgery. This report describes endovascular coiling of a saphenous vein graft aneurysm that developed after redo coronary artery bypass grafting. The aneurysm occurred in a proximally occluded saphenous vein graft after revascularization of the same target vessel. The procedure required a retrograde approach through a patent left internal mammary and left anterior descending artery to reach and successfully thrombose the aneurysm.


Assuntos
Aneurisma/etiologia , Aneurisma/cirurgia , Veia Safena/transplante , Angioplastia/instrumentação , Ponte de Artéria Coronária/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...